Service-Pack 2025-9#

SOFiSTiK Structural Desktop#

Cross Sections and Materials#

Bugfix

  • SSD dialog for standard cross section column: In the case of symmetric reinforcement definitions ‘Symmetric (My) / (Mz)’ the reinforcement calculator was corrected for the absolute reinforcement.

Life Cycle Assessment (LCA)#

General

  • The Ökobaudat datasets are now available separately based on their background data (Sphera MLC and ecoinvent) and have been updated with the latest values.

Interactive Pre- and Postprocessors#

Graphic#

Graphical Representation of FE Structures and Results

Bugfix

  • Better representation of QUAD tendon results. (242333)

  • Sometimes the storey level result Uz shows a wrong vector direction.

  • Sometimes the toolbar positions were not stored in the registry.

  • The welding stresses on cuts according to EC 1993-1-8 are currently not calculated correctly. They are therefore no longer offered until they have been revised. (243915)

FEA Modules for Batch Processing#

TENDON#

Geometry and Forces of Tendons

Bugfix

  • Fixed incorrect elongations in PLB when slip = 0 or not applied (e.g., using PSIG ANWS TRW). (244856)

CSM#

Construction Stage Manager

Bugfix

  • CSM superposition: loadcase title added for pile element bedding. (245029)

ASE#

General Structural Analysis of FE Structures

Bugfix

  • Strain energy report corrected for nonlinear beam elements. (237342)

  • Center of mass on eigenvalue analysis corrected on MASS FACT input. (244147)

ELLA#

Extended Live Load Analysis

Bugfix

  • Correction regarding the handling of load trains with different wheel spacings for transverse influence lines. (243835)

BEMESS#

Design of Plates and Shells

Bugfix

  • SLS checks did not run using CTRL SLS V2 1 for CAPRA MAURY - corrected. (244138)