Service-Pack 2025-6#
SOFiSTiK Structural Desktop#
General Information#
Task Action Manager: Modifications are now saved directly to the CDB.
IFC/SAF Data Exchange#
Bugfix
IFC Export
A structural member with different end cross sections and multiple inner voids is now correctly exported. (237802)
Cross Sections and Materials#
Bugfix
Sometimes an empty SECT record in the CADINP input did not work as the end of the current section.
Missing steel profiles of the AISC “HSS 12 x 12 x …” or “HSS 304.8 x 304.8 x …” added. (236656)
The default for missing profile selectors was sometimes wrong.
Sometimes the material testing of stress points leads to a false warning.
The preview of the steel profile dialogue shows an incorrect shear centre for U and C profiles.
Earthquake RSA - Buildings#
Bugfix
Decimal places in the mass participation filtering input for the Earthquake RSA tasks were not taken into account during the calculation.
Horizontal storey extensions were not correctly accounted for in the case of towers and the associated accidental eccentricities.
Combinations and Superpositions#
General
MAXIMA: The fully-automatic assignment of the result load case numbers is marked as obsolete, and will no longer be supported in the next Release v2026.
Life Cycle Assessment (LCA)#
General
The EPDs available in the LCA Task have been updated to the latest version of Ökobaudat.
Bugfix
Excel Export of Design Element GWP results was not correct if secondary groups were deselected.
Interactive Pre- and Postprocessors#
Graphic#
Graphical Representation of FE Structures and Results
Bugfix
Sometimes design element results were not offered. (237896)
Sometimes structure lines were displayed incorrectly.
FEA Modules for Batch Processing#
SOFiMSHC#
Geometric Modelling
Bugfix
Prevent marking of structural points along secondary axes as explicitly created, so that they can be successfully merged with other, coinciding, user-defined structural points. (239208)
Added missing export values.
SOFiLOAD#
Loads and Load Functions
Bugfix
Sometimes the stored QUAD group number of loads on structural elements with automatic references was incorrect. (237932)
Correction of the point load values for the load train: Type 12, Locomotive-hauled freight train acc. Eurocode (RFAT 12). (238827)
TENDON#
Geometry and Forces of Tendons
Bugfix
Fixing scaling of duct/tendon labels in plan/elevation views when font size is changed. (238069)
Modified behavior of PLOT PCS for tendon overviews. (238069)
Tendons do not longer exceed picture dimensions
PCS now allows a scaling of the overview section
CSM#
Construction Stage Manager
Bugfix
Creep and shrinkage values on haunched quad slabs now depending on individual slab thickness.
ASE#
General Structural Analysis of FE Structures
Bugfix
- -Time step analysis: now the kinematic energy is calculated and stored for plots, see example
ase_nstr_pld_pile_crash.dat (236702)
Time step analysis with KF couplings and alpha Methode (STEP…THE 0.7): oszillations prevented. (237711)
Strain loads on simple beams manipulated with GRP…FACS corrected for TH3.
Pile element dead load was influenced by GRP2…ST_M : corrected. (239605)
Halfspace feature DPDS extended for CSM staged analysis.
BEMESS#
Design of Plates and Shells
Bugfix
Punching: Deduction of dead load over columns now always and not only in case of design loadcases.
Detection of punching nodes over wall with rotational hinges improved. (237741)
Punching: analysis of perimeter u1 corrected for wall ends. 238180
Stress check: Missing marker F for “stress check concrete” corrected for WINGRAF origin of reinforcement. (239155)
Find support width of bedded boundaries improved.