Bugfix
Prestressing steel “SNIB 500” corrected to reinforcing steel “SNIA 500B” according to SP 52-101-2003. (246454)
In the case of wide webs of box girders with a continuous shear cut the resistance 1/WTm was corrected. (246999)
Interactive Pre- and Postprocessors#
Viewer#
Interactive System Visualization Tool
Bugfix
Fixed a crash occurring when closing the standalone Viewer, present since March (caused by an incorrect COM uninitialization order).
Result Viewer#
Graphical and Tabular Post-Processing
Bugfix
Sometimes, after an interactive selection of the beam section, an incorrect cross-section number was used for the cross-section stresses of beams (or structural elements or external beam sections). (246436)
FEA Modules for Batch Processing#
TENDON#
Geometry and Forces of Tendons
Bugfix
Fixed incorrect “is inside box-girder” check. Falsely detected distant cross-sections as box-girder. (246095)
ELLA#
Extended Live Load Analysis
Bugfix
Correction to the handling of transversal springs defined by two separate nodes.
BEMESS#
Design of Plates and Shells
Bugfix
Punching longitudinal reinforcement for WINGRAF had been faded out too much near punching nodes at wall ends, corrected. (246303)